Understanding the Error
MySQL Error 1277, SQLSTATE HY000 (ER_BAD_SLAVE_UNTIL_COND), is encountered when there is an incorrect parameter or combination of parameters specified in the START SLAVE UNTIL
command. This command is used in replication setups to control the replication slave, specifying conditions for the slave to execute before stopping.
Diagnosing the Issue
To diagnose this error, you need to examine the START SLAVE UNTIL
command you’ve issued. The command has a specific syntax and expects certain types of parameters. Here is the general syntax:
START SLAVE UNTIL
MASTER_LOG_FILE = 'log_name',
MASTER_LOG_POS = log_pos;
MASTER_LOG_FILE
refers to the name of the master binary log file.MASTER_LOG_POS
refers to the position in the master binary log file to which the slave should execute.
Errors can occur if the log file name or log position are incorrect, or if the parameters do not match the actual data from the master server.
Solutions to Fix Error 1277
Correct Log File and Position
Ensure that the log file and position you are referencing exist and are correct. You can find the current binary log file and its position on the master server using:
SHOW MASTER STATUS;
This will give you the current binary log file and the position to use. Here’s an example of a corrected START SLAVE UNTIL
command:
START SLAVE UNTIL
MASTER_LOG_FILE = 'mysql-bin.000001',
MASTER_LOG_POS = 107;
Using Relay Log Position
Alternatively, you can use the relay log position to start the slave until a specific event in the relay log is executed:
START SLAVE UNTIL
RELAY_LOG_FILE = 'relay-log.000001',
RELAY_LOG_POS = 4;
Again, ensure that the relay log file and position are correct. You can find this information on the slave server using:
SHOW SLAVE STATUS;
Using SQL_BEFORE_GTIDS or SQL_AFTER_GTIDS
If you are using GTID-based replication, you can also use SQL_BEFORE_GTIDS
or SQL_AFTER_GTIDS
to specify a set of GTIDs that the slave should execute before stopping:
START SLAVE UNTIL
SQL_BEFORE_GTIDS = 'uuid_set';
or
START SLAVE UNTIL
SQL_AFTER_GTIDS = 'uuid_set';
Ensure that the GTID set is correctly formatted and valid.
Checking for Syntax Errors
Check for any syntax errors in the command. The error might be due to a misplaced comma, incorrect quotes, or other syntax issues. Refer to the official MySQL documentation for the exact syntax.
Conclusion
When faced with MySQL Error 1277, it’s crucial to verify that the parameters used in the START SLAVE UNTIL
command are correct and that the syntax is accurate. By carefully checking the master log file, log position, and ensuring that the parameters match the master server’s data, you can resolve this error and successfully control the replication process according to your requirements.